Welcome to China Electron !

LTV-217-TP1-B-G

Model

LTV-217-TP1-B-G

Category

optoelectronics
optocouplers

The Lite-On LTV-217-TP1-B-G provides robust optoisolation with 3.75kV isolation, 80V load capability, and industrial temperature range (-55°C to +110°C). Ideal for noise-prone control systems and medical devices, it features 30mA output, 1.2V forward voltage, and 50-600% CTR. Designers should prioritize proper layout with 3mm isolation gaps, thermal management at 50°C/W, and verify compatibility with logic levels. Best suited for applications requiring stable isolation in harsh environments with voltage up to 80V.

Reference Pricing

5+ :$0.0714
50+ :$0.0518
150+ :$0.0504
500+ :$0.0476
3000+ :$0.0364
6000+ :$0.0392

Reference Stock

Available:Unknown

Specifications

Data Transfer Rate50% at l_F=5mA V_CE=5V
Fall Time3μs
Isolation Voltage170Vrms
Operating Temperature Range-55~+125℃
Output Voltage80V
Package TypeSOIC-4-175mil
Rated Voltage80V
Rise Time0.6μs
Transistor Output Current50mA

Function And Role

Core Function

Optoisolates input and output circuits to prevent noise and voltage transients

Key Characteristics

  • 80V load voltage
  • 3.75kV isolation voltage (Vrms)
  • 30mA output current
  • 1.2V forward voltage (Vf)
  • 6V reverse voltage (Vr)
  • 400mV VCE(sat) at 2.4mA/8mA
  • Operating temperature: -55°C to +110°C
  • Rise time: 600ns
  • Fall time: 3μs
  • Current Transfer Ratio (CTR): 50% to 600%

Application Domains

Basic Scenarios

  • Industrial control systems
  • Medical device signal isolation
  • Consumer electronics power isolation

Extended Scenarios

  • Renewable energy system inverters
  • Automotive electronic control units
  • Telecommunication infrastructure

Precautions

Soldering

Use 260-300℃ soldering temperature with 20-30s hold time

Current Limit

Max continuous output current: 30mA

Voltage Limit

Input voltage ≤80V, isolation voltage ≥3.75kV

Thermal Management

Thermal resistance: 50°C/W (TA0.2)

Storage

Store in <5% RH, -40°C to +85°C environment

Risk Warnings
  • Avoid static discharge damage
  • Prevent reverse bias exceeding 6V
  • Do not exceed 110°C operating temperature

Alternative Model Params

  • Load voltage (≤80V)
  • Isolation voltage (≥3.5kV)
  • Output current (≤35mA)
  • Forward voltage (≤1.5V)
  • Operating temperature range (-40°C to +125°C)

Design Recommendations

Layout

Maintain ≥3mm isolation gap between input/output

Thermal

Use 0.5W heat sink for high current applications

Compatibility

Verify with 5V/3.3V logic levels

Testing

Perform 100% visual inspection before assembly

Market Positioning

Strengths
  • High cost-to-isolation ratio
  • Industrial temperature grade
  • RoHS compliant
  • 400mV saturation voltage
Weaknesses
  • Limited to ≤30mA output
  • Higher CTR variance at extremes
  • No built-in surge protection

Datasheet